top of page

120V AC 2-in-1 LED Strobe and 10-Year Talking Smoke Alarm 
P4010ACLEDSCA

Advanced protection for the deaf and hard of hearing. Meets Visual Signaling Requirement for Ontario Building Code.

  • 177 Candela Strobe synchronizes with matching interconnected strobe alarms, during an alarm event. Powered by Cree® LEDs.

  • 120 V hardwired with 10-year sealed battery backup (on smoke alarm)

  • Voice calls out danger

  • Low profile - Smaller unit that homebuilders and homeowners can be happy about displaying in their homes.

  • cUL Listed

120V AC Talking Smoke & Carbon Monoxide Alarm with Front-Load AA Battery Backup 
900-0119

Provides protection from two hazards – fire and CO – in one unit.

  • Combined Smoke & Carbon Monoxide Alarm – A single unit can be installed where previously, two were needed. Reduces installation time and protects against both fire and carbon monoxide dangers.

  • Intelligent Sensor Technology – Combines the detection capabilities of an ionization smoke sensor with that of an electrochemical carbon monoxide sensor. When either sensor notices a potential hazard, the alarm will adjust its smoke sensitiivity to differentiate between a real hazard and a false one. 

  • Voice Warning – Announces the hazard type detected (in English and French). Alarm announces “FIRE!” when a smoke or fire hazard is detected and announces “WARNING! CARBON MONOXIDE!” when a CO hazard is detected. Also announces “LOW BATTERY” when it is time to replace the batteries. 

  • 120 V Interconnectable – Will interconnect with up to 24 other devices (18 of which can be initiating), including smoke alarms (limit of 12), CO and heat alarms.

  • AA Front-Loading Battery Backup – Change batteries without the need to remove the unit from the ceiling, providing continuous protection in the case of a power outage.

  • Tamper Resistant – Unit will lock to mounting bracket to deter theft or tampering.

  • End of Life Notification – Ten (10) years after unit is first powered, this alarm will beep two times every 30 seconds to indicate it is time to replace the alarm.

  • Alarm Memory: The green LED will flash every second during alarm. When the alarm condition goes away, the originating alarm unit will flash the green LED every 16 seconds until the Test / Reset button is pressed, thus resetting the alarm. 

  • Multi-function One Button Design includes:

    • Test Feature – Tests the alarm circuitry and triggers the voice announcement

    • Hush® Feature – Temporarily silences nuisance alarms for approximately 9 minutes (will announce “HUSH MODE ACTIVATED,” or “HUSH MODE CANCELLED.”).

    • Reset Feature – Resets the carbon monoxide alarm

    • Peak Level Memory – If alarm has detected a CO level of 100ppm or higher since it was last reset, the voice alarm will announce “CAUTION, CARBON MONOXIDE PREVIOUSLY DETECTED

120V AC 3-in-1 LED Strobe and 10-Year Talking Smoke & CO Alarm 
P4010ACLEDSCOCA

Advanced 3-in-1 protection. Meets Visual Signaling Requirement for Ontario Building Code.

  • 177 Candela Strobe synchronizes with matching interconnected P4010 series strobe alarms, during an alarm event. Powered by Cree® LEDs.

  • 120 V hardwired with 10-year sealed battery backup (on smoke and carbon monoxide alarm)

  • Voice calls out danger

  • Low profile - Smaller unit that homebuilders and homeowners can be happy about displaying in their homes.

  • cUL- and CSA-Listed

LED Strobe Light 
SLED177iCA

The Kidde SLED177iCA, used in conjunction with a smoke, heat or carbon monoxide alarm, provides a bright visual signal to warn of a smoke, heat or CO hazard. 

  • The Kidde Strobe light benefits the hearing impaired, allowing a visual alert of a danger.

  • This unit also includes a tamper resist pin that helps to deter thief and tampering.

  • The Kidde SLED177iCA, used in conjunction with a smoke, heat or carbon monoxide alarm, provides a bright signal to warn of a smoke, heat or CO hazard.

bottom of page